How to Calibrate Your Hach pH Probe

A Hach pH probe is a valuable tool for measuring the acidity or alkalinity of a solution. However, in order to ensure accurate readings, it is important to calibrate your pH probe regularly. Calibration is the process of adjusting the probe to accurately measure pH Levels. In this article, we will discuss how to calibrate your Hach pH probe to ensure precise and reliable results.

Before calibrating your pH probe, it is important to gather all the necessary materials. You will need calibration buffers of known pH values, typically pH 4.01 and pH 7.00, as well as a clean container to hold the buffers. It is also recommended to have a small amount of distilled water on hand to rinse the probe between calibrations.


To begin the calibration process, first ensure that the pH probe is clean and free of any debris. Rinse the probe with distilled water to remove any residue that may affect the accuracy of the readings. Once the probe is clean, place it in the pH 7.00 buffer solution and allow it to stabilize. The probe should be fully submerged in the buffer solution, and the reading on the pH meter should stabilize within a few seconds.

Once the reading has stabilized, adjust the calibration trimmer on the pH meter until the display reads the correct pH value of 7.00. This may require turning a small screw or knob on the meter to fine-tune the calibration. Once the pH meter is calibrated to the pH 7.00 buffer solution, remove the probe and rinse it with distilled water.

Next, place the probe in the pH 4.01 buffer solution and allow it to stabilize. Again, adjust the calibration trimmer on the pH meter until the display reads the correct pH value of 4.01. This may require further fine-tuning of the calibration to ensure accurate readings.

After calibrating the pH meter to both the pH 7.00 and pH 4.01 buffer solutions, rinse the probe with distilled water to remove any residual buffer solution. Your Hach pH probe is now calibrated and ready for use.

Controller type ROC-7000 Single-stage/Double-stage Reverse osmosis control integrated system
\\u3000 Cell constant 0.1cm-1 1.0 cm-1 10.0cm-1
Conductivity \\u00a0measurement parameters Raw water conductivity \\u3000 \\u3000 \\u3000 \\uff080\\uff5e2000\\uff09 \\uff080\\uff5e20000\\uff09
\\u3000 Primary conductivity \\u3000 \\uff080\\uff5e200\\uff09 \\uff080\\uff5e2000\\uff09 \\u3000
\\u3000 Secondary conductivity \\u3000 \\uff080\\uff5e200\\uff09 \\uff080\\uff5e2000\\uff09 \\u3000
\\u3000 Temperature compensation Automatic compensation\\u00a0on the basis of 25 \\u2103 ,compensation range\\uff080\\uff5e50\\uff09\\u2103
\\u3000 Accuracy Matched precision\\uff1a1.5\\u00a0level
Flow measurement\\u00a0range Instantaneous flow \\uff080\\uff5e999\\uff09m3/h
Accumulative\\u00a0flow \\uff080\\uff5e9999999\\uff09m3
pH Measurement range 2-12
measurement parameters Accuracy \\u00b10.1pH
\\u3000 Temperature compensation Automatic compensation\\u00a0on the basis of 25 \\u2103 ,compensation range\\uff080\\uff5e50\\uff09\\u2103
DI\\u00a0acquisition Input signal Low pressure switch\\u00a0of Tap water,high level\\u00a0of\\u00a0pure water tank, low level\\u00a0of pure water tank, low pressure switch before the pump, high pressure switch after the primary\\u00a0booster pump,high level\\u00a0of\\u00a0secondary\\u00a0pure water tank, low level\\u00a0of secondary\\u00a0pure water tank,high pressure switch after the secondary\\u00a0booster pump
Signal Type Passive switch contact
DO\\u00a0Control Control output Inlet valve, primary\\u00a0flush valve, primary drain valve,\\u00a0antiscalant pump,\\u00a0raw water pump, primary booster pump, secondary booster pump, secondary flush valve, secondary drain valve, pH adjustment metering pump.
Electrical contact Relay\\uff08ON/OFF\\uff09
Load capacity 3A(AC 250V)~ 3A(DC 30V)
Display\\u00a0screen Screen\\u00a0color:TFT\\uff1bresolution:800\\u00d7480
Working power Working power DC 24V\\u00b14V
Power consumption \\u22646.0W
Working Environment Temperature:(0\\uff5e50)\\u2103\\uff1bRelative humidity:\\u226485%RH\\uff08non\\u00a0condensation\\uff09
Storage environment Temperature:\\uff08-20\\uff5e60\\uff09\\u2103\\uff1bRelative humidity:\\u226485%RH\\uff08non\\u00a0condensation\\uff09
Installation Panel mounted Hole\\uff08Length\\u00d7Width\\uff0c192mm\\u00d7137mm\\uff09

It is important to note that pH probes should be calibrated regularly to ensure accurate readings. Factors such as temperature, age of the probe, and exposure to harsh Chemicals can affect the accuracy of pH measurements. By calibrating your pH probe before each use, you can ensure that your readings are precise and reliable.

In conclusion, calibrating your Hach pH probe is a simple yet crucial step in ensuring accurate pH measurements. By following the steps outlined in this article and calibrating your pH probe with known buffer solutions, you can trust that your readings are accurate and reliable. Remember to calibrate your pH probe regularly to maintain its accuracy and performance.