How to calibrate the Hach HQ40D portable water quality meter

The Hach HQ40D portable water quality meter is a versatile and reliable tool used by professionals in various industries to measure and monitor water quality parameters. Calibration is an essential step in ensuring the accuracy and reliability of the measurements taken by the meter. In this article, we will guide you through the process of calibrating the Hach HQ40D portable water quality meter.

Before you begin the calibration process, it is important to gather all the necessary equipment. You will need calibration standards for the parameters you wish to calibrate, such as pH buffer solutions for pH calibration or conductivity standards for conductivity calibration. Make sure that the calibration standards are fresh and have not expired, as using expired standards can Lead to inaccurate calibration results.

To start the calibration process, turn on the Hach HQ40D portable water quality meter and allow it to warm up for at least 15 minutes. This will ensure that the meter is operating at its optimal performance level. Once the meter is ready, navigate to the calibration menu by pressing the menu button on the meter.

Select the parameter you wish to calibrate, such as pH or conductivity, and follow the on-screen instructions to initiate the calibration process. The meter will prompt you to immerse the sensor in the calibration standard solution and wait for the reading to stabilize. Once the reading has stabilized, press the enter button to confirm the calibration.

It is important to rinse the sensor with deionized water between calibration standards to prevent cross-contamination and ensure accurate calibration results. Repeat the calibration process for each parameter you wish to calibrate, following the same steps outlined above.


After calibrating all the parameters, it is recommended to perform a verification check to ensure the accuracy of the calibration. This can be done by measuring a known standard solution and comparing the reading to the expected value. If the readings are within an acceptable range, the calibration is successful.

It is important to note that calibration should be performed regularly to maintain the accuracy of the measurements taken by the Hach HQ40D portable water quality meter. Factors such as sensor drift, environmental conditions, and usage frequency can affect the calibration of the meter, so it is recommended to calibrate the meter at least once a month or whenever there are significant changes in the measurement results.

Product Model DOF-6310\\u00a0(DOF-6141)
Product Name Dissolved oxygen data collection terminal
Measuring Method Fluorescence Method
Measurement range 0-20mg/L
Accuracy \\u00b10.3mg/L
Resolution \\u00a0\\u00a0 0.01mg/L
Response time 90s
Repeatibility 5%RS
Temperature compensation 0-60.0\\u2103 Accuracy:\\u00b10.5\\u2103
Air pressure compensation 300-1100hPa
Stand pressure 0.3Mpa
Communication RS485 MODBUS-RTU standard protocol
Power DC(9-28)V
Power comsuption <2W
Operational envrionment Temperature:(0-50)\\u2103
Storage Environment Temperature:(-10-60)\\u2103;\\u00a0Humidity:\\u226495%RH(None condensation)
Installation Submerged
Protection Level IP68
Weight 1.5Kg(with 10m cable)

In conclusion, calibrating the Hach HQ40D portable water quality meter is a straightforward process that is essential for ensuring accurate and reliable measurements. By following the steps outlined in this article and performing regular calibrations, you can trust that your meter is providing you with precise water quality data for your applications.