Table of Contents
Advantages of Dry Type Transformers for Industrial Applications
Transformers are essential components in electrical systems, as they help to regulate voltage Levels and ensure the safe and efficient distribution of electricity. When it comes to industrial applications, choosing the right type of transformer is crucial to the overall performance and reliability of the system. Two common types of transformers used in industrial settings are dry type transformers and oil-immersed transformers.
Dry type transformers, as the name suggests, do not use oil as a cooling medium. Instead, they rely on air to dissipate heat generated during operation. This makes them a popular choice for indoor applications where the use of oil may pose a Safety hazard. Dry type transformers are also more environmentally friendly, as they do not require the use of oil, which can be harmful if leaked or spilled.
One of the key advantages of dry type transformers is their ability to operate efficiently in a wide range of environmental conditions. They are not affected by temperature fluctuations or moisture, making them ideal for use in harsh industrial environments. Additionally, dry type transformers are easier to install and maintain compared to oil-immersed transformers, as they do not require the use of a containment pit or regular oil testing and maintenance.
model | Rated\\u00a0capacity\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0Current\\u00a0(%) | Short-circuit\\u00a0impedance\\u00a0(%) |
SH15-M-30 | 30 | 6,6.3,10,10.5,11/0.4 | 33 | 630 | 1.50 | 4.0 |
SH15-M-50 | 50 | 6,6.3,10,10.5,11/0.4 | 43 | 910 | 1.20 | 4.0 |
SH15-M-63 | 63 | 6,6.3,10,10.5,11/0.4 | 50 | 1090 | 1.10 | 4.0 |
SH15-M-80 | 80 | 6,6.3,10,10.5,11/0.4 | 60 | 1310 | 1.00 | 4.0 |
SH15-M-100 | 100 | 6,6.3,10,10.5,11/0.4 | 75 | 1580 | 0.90 | 4.0 |
SH15-M-125 | 125 | 6,6.3,10,10.5,11/0.4 | 85 | 1890 | 0.80 | 4.0 |
SH15-M-160 | 160 | 6,6.3,10,10.5,11/0.4 | 100 | 2310 | 0.60 | 4.0 |
SH15-M-200 | 200 | 6,6.3,10,10.5,11/0.4 | 120 | 2730 | 0.60 | 4.0 |
SH15-M-250 | 250 | 6,6.3,10,10.5,11/0.4 | 140 | 3200 | 0.60 | 4.0 |
SH15-M-315 | 315 | 6,6.3,10,10.5,11/0.4 | 170 | 3830 | 0.50 | 4.0 |
SH15-M-400 | 400 | 6,6.3,10,10.5,11/0.4 | 200 | 4520 | 0.50 | 4.0 |
SH15-M-500 | 500 | 6,6.3,10,10.5,11/0.4 | 240 | 5140 | 0.50 | 4.0 |
SH15-M-630 | 630 | 6,6.3,10,10.5,11/0.4 | 320 | 6200 | 0.30 | 4.5 |
SH15-M-800 | 800 | 6,6.3,10,10.5,11/0.4 | 380 | 7500 | 0.30 | 4.5 |
SH15-M-1000 | 1000 | 6,6.3,10,10.5,11/0.4 | 450 | 10300 | 0.30 | 4.5 |
SH15-M-1250 | 1250 | 6,6.3,10,10.5,11/0.4 | 530 | 12000 | 0.20 | 4.5 |
SH15-M-1600 | 1600 | 6,6.3,10,10.5,11/0.4 | 630 | 14500 | 0.20 | 4.5 |
SH15-M-2000 | 2000 | 6,6.3,10,10.5,11/0.4 | 750 | 18300 | 0.20 | 5.0 |
SH15-M-2500 | 2500 | 6,6.3,10,10.5,11/0.4 | 900 | 21200 | 0.20 | 5.0 |
Another advantage of dry type transformers is their compact size and lightweight design. This makes them easier to transport and install, especially in areas where space is limited. In addition, dry type transformers are less prone to leaks and spills, reducing the risk of downtime and costly repairs.
On the other hand, oil-immersed transformers use oil as a cooling medium to dissipate heat generated during operation. While they are more efficient at cooling compared to dry type transformers, they require regular maintenance to ensure the oil is clean and free of contaminants. Oil-immersed transformers are also larger and heavier than dry type transformers, making them more difficult to transport and install.
When it comes to choosing between dry type and oil-immersed transformers for industrial applications, it ultimately comes Down to the specific requirements of the system. While oil-immersed transformers may offer higher efficiency and better cooling capabilities, dry type transformers are often preferred for their ease of installation, maintenance, and environmental friendliness.
In China, there are many manufacturers and exporters of both dry type and oil-immersed transformers. These companies offer a wide range of transformer products to meet the needs of industrial customers. With competitive pricing and high-quality products, Chinese transformer manufacturers have gained a reputation for providing excellent value for money.
To learn more about the advantages of dry type transformers for industrial applications, many Chinese transformer manufacturers offer informative videos on their websites. These videos provide valuable insights into the design, construction, and operation of dry type transformers, helping customers make informed decisions when choosing a transformer for their industrial system.
In conclusion, dry type transformers offer several advantages for industrial applications, including ease of installation, maintenance, and environmental friendliness. While oil-immersed transformers may offer higher efficiency and better cooling capabilities, dry type transformers are often preferred for their compact size, lightweight design, and versatility in harsh environments. With the help of Chinese transformer manufacturers and exporters, industrial customers can find high-quality transformer products at a competitive price ratio.
How to Choose the Right Oil Immersed Transformer for Your Power Distribution Needs
When it comes to power distribution, transformers play a crucial role in ensuring that electricity is efficiently transmitted from one place to another. There are various types of transformers available in the market, each with its own set of advantages and disadvantages. Two common types of transformers are dry type and oil immersed transformers, both of which are used for different applications depending on the specific requirements of the power distribution system.
Dry type transformers, as the name suggests, do not use any liquid coolant for insulation. Instead, they rely on air or solid insulation materials to prevent electrical arcing and short circuits. These transformers are typically used in indoor applications where fire safety is a concern, as they do not pose the risk of oil leaks or spills. However, dry type transformers are generally less efficient than oil immersed transformers and are not suitable for high voltage applications.
On the other hand, oil immersed transformers use oil as a coolant and insulating medium. The oil helps to dissipate heat generated during operation, allowing the transformer to operate at higher temperatures without overheating. Oil immersed transformers are commonly used in outdoor applications where space is not a constraint, such as in substations or power plants. These transformers are more efficient than dry type transformers and can handle higher voltage levels, making them ideal for long-distance Power Transmission.
When choosing between dry type and oil immersed transformers, it is important to consider the specific requirements of your power distribution system. If fire safety is a concern and space is limited, a dry type transformer may be the best option. However, if efficiency and high voltage capabilities are more important, an oil immersed transformer would be the better choice.
Dry transfo | Rating\\u00a0capacity\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09 |
SC11-30 | 30 | 6,6.3,6.6,10,11/0.4 | 180 | 710 | 2.4 | 4.0 |
SC11-50 | 50 | 6,6.3,6.6,10,11/0.4 | 250 | 1000 | 2.4 | 4.0 |
SC11-80 | 80 | 6,6.3,6.6,10,11/0.4 | 340 | 1380 | 1.8 | 4.0 |
SC11-100 | 100 | 6,6.3,6.6,10,11/0.4 | 360 | 1570 | 1.8 | 4.0 |
SC11-125 | 125 | 6,6.3,6.6,10,11/0.4 | 420 | 1850 | 1.6 | 4.0 |
SCB11-160 | 160 | 6,6.3,6.6,10,11/0.4 | 490 | 2130 | 1.6 | 4.0 |
SCB11-200 | 200 | 6,6.3,6.6,10,11/0.4 | 560 | 2530 | 1.4 | 4.0 |
SCB11-250 | 250 | 6,6.3,6.6,10,11/0.4 | 650 | 2760 | 1.4 | 4.0 |
SCB11-315 | 315 | 6,6.3,6.6,10,11/0.4 | 790 | 3470 | 1.2 | 4.0 |
SCB11-400 | 400 | 6,6.3,6.6,10,11/0.4 | 880 | 3990 | 1.2 | 4.0 |
SCB11-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1050 | 4880 | 1.2 | 4.0 |
SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1210 | 5880 | 1.0 | 4.0 |
SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1170 | 5960 | 1.0 | 6.0 |
SCB11-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1370 | 6960 | 1.0 | 6.0 |
SCB11-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1590 | 8130 | 1.0 | 6.0 |
SCB11-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 1880 | 9690 | 1.0 | 6.0 |
SCB11-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2210 | 11730 | 1.0 | 6.0 |
SCB11-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 2720 | 14450 | 0.8 | 6.0 |
SCB11-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3200 | 17170 | 0.8 | 6.0 |
In addition to the type of transformer, it is also important to consider the mounting configuration. Ground mounted transformers are installed on a concrete Pad or platform, typically outdoors. These transformers are easy to access for maintenance and do not require any special infrastructure for installation. However, they may be more susceptible to environmental factors such as moisture and temperature fluctuations.
As a China exporter and maker of transformers, we offer a wide range of high-quality products at competitive prices. Our transformers are designed to meet international standards for efficiency and reliability, ensuring that your power distribution system operates smoothly and safely. We also provide technical support and after-sales service to help you with installation, maintenance, and troubleshooting.
To learn more about our products and services, we invite you to visit our website or contact us directly. We also offer videos and other resources to help you choose the right transformer for your specific needs. With our high price ratio and commitment to customer satisfaction, we are confident that we can provide you with the best solution for your power distribution requirements.